Type: MULTIFLEX-SOFT 8x4 mm2, black Nominal voltage: 300/500 V Conductor: finely wired acc. to VDE 0295 Core insulation: PVC-mixture – shorehardness 90+/- 3 Jacket: Soft PVC-mixture, black (RAL 9005) Shorehardness 65 +/- 3 Presure extrusion, with talc, printing: optional Outside diameter: approx. 21.9 ± 0,40 mm Test voltage > 3 kV – at 50 Hz eff. for 1 minute Insulation resistance: min. 20 MOhm x km at 20°C Conductor resistance: max. 7,98 Ohm/km at 20°C Operating voltage: max. 500 V Temperature rating: static: -30 up to +80 °C operating: - 5 up to +70 °C This cable is flame retardant acc. DIN VDE 0482 part 265-2-1
Procable softflex 8x4mm² black - Thin Fexible version
Procable softflex 8x4mm² black FLEX
Outer Diameter 14,6mm
Constructional Properties
Conductor: Stranded annealed copper wires (50x0.3 mm / Class 5) Insulation: PVC (Polyvinyl Chloride) - (nom. wall thickness: 0.50 mm) Lay-up: Cores stranded in layers (with a center filler) Talcum Powder: Yes Sheath: FLEX NPVC (Nitril PVC-Polyvinyl Chloride) - (with pressure extrusion) Cable Colour: RAL9005-Black / UV Res. as per ISO 4892-3 Standard: with reference to VDE0245
Technical Properties (20°C)
Operating Voltage: 300/500 V Test Voltage: 3.5 kV Min. Insulation Resistance: 20 M ohm x km Operating Temp. Fixed: -40°C...+70°C Installation Temperature: -5°C...+70°C Flame Propagation: IEC 60332-1-2 Min. Bending Radius: 8 x Cable Diameter